Fuel Injector: Service Precautions

Fuel Injectors, Cleaning

-

Remove fuel injectors => [ Fuel Injectors ] See: Service and Repair.

‹› Follow the safety precautions and the instructions for the ultrasonic device.

-

The ultrasonic device must be filled with the included cleaner. 

‹› Fill the ultrasonic device up to the upper edge of the holes with cleaner (see the magnified area of the illustration).

-

Insert fuel injectors - 1 - into bracket -  2 - as far as stop.

-

Dip fuel injectors with bracket into cleaner.

-

Adjust temperature to 50 degrees using knob - 4 -. 

-

Set a cleaning time of 30 minutes using knob - 5 -. 

-

Switch ultrasonic device on with button - 3 -.

‹› The time begins counting down once the cleaning temperature reaches 50 degrees.

-

Replace combustion chamber seal (Teflon seal) after cleaning each fuel injector => [ Teflon Combustion Chamber Seal, Replacing ] See: Service
and Repair.