Remove the center noise insulation - fasteners 1 through 3 -.

-

Disconnect the connector - 2 - on the back-up lamp switch (F4).

-

Remove the nut - 1 - and remove the bracket with the electric wire from the threaded bolt.

-

Remove the lower screw on the starter and remove the starter.

Installing

Install in reverse order of removal, noting the following:

-

Connect battery. Required actions =>  See: Battery/Service and Repair/Removal and Replacement/Battery, Engine Compartment, Disconnecting
and Connecting. 

Tightening Specifications