A3 Quattro V6-3.2L (BUB) (2008)
Air Door Actuator / Motor: Service and Repair
Recirculation Door Motor, With Air Flow Door Motor
Recirculation Door Motor, with Air Flow Door Motor
Removing
-
Remove the glove compartment.
-
Mark connector - A - if necessary (to rule out an interchange in the event several connectors are disconnected at the same time).
-
Disconnect the connector - A -.
-
Disengage catches - C - and - D - for bracket - B - on intake housing and remove bracket - B - (toward rear).
-
Remove positioning motor - A - from air intake shroud.
Installing
-
Check shaft of recirculation door - C - before installing control motor - A -.
-
Set shaft - C - so that connecting element of control motor - D - can be inserted.
-
Insert control motor with connecting element - D - into shaft - C - and mounts at intake housing - B -.
-
Install the bracket - A -, make sure the guides on the bracket - B - are inserted correctly into the intake housing mount - C - and that the bracket is
engaged correctly in both catches - D - and - E -.