audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Duct > < Air Distribution Flexible Shaft|Page 7481
Page 2
background image

‹› To prevent the instrument panel shell from damage, instrument panel should be placed on a clean work bench which is covered with clean

cardboard. 

-

Disengage lug - D - of Bowden cable sheath -  E - and remove Bowden cable sheath from mount of base plate for heater controls.

-

Disengage ball on Bowden cable - F - from operating lever - G -

-

Disengage support bracket - A - of Bowden cable sheath -  E - and remove Bowden cable sheath from heater guide - C -. 

-

Disengage ball on Bowden cable - B - from temperature door lever.

Installing

Installation is carried out in the reverse order, when doing this note the following:

-

Only install a Bowden cable which has not been kinked and can move easily in Bowden cable sheath.

-

Do not kink Bowden cable.

Air Duct > < Air Distribution Flexible Shaft|Page 7481