audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heater Control Module, Checking|Page 7638 > < Heater Control Module|Page 7635
Page 1
background image

Control Module HVAC: Testing and Inspection
Heater Control Module, Checking

Heater Control Module, Checking

‹› Beginning with MY 2010, a Start/Stop System is offered as an option on certain engines. The Heater Control Module (J65) has no affect on the

Start/Stop function on vehicles with only a heater (no "A/C").

-

Remove the glove compartment. See: Body and Frame/Interior Moulding / Trim/Utility Storage Compartment/Service and Repair/Storage
Compartments and Covers/Glove Compartment

-

Switch ignition on.

-

Turn rotary switch for air distribution - B - into " air distribution to instrument panel vents" position.

-

The fresh/recirculating air button - F - is not operated (fresh air mode, button indicator light does not come on).

-

Connect the Voltage Tester (V.A.G 1527 B) - B - to check voltage at connector - A - between terminals "9" and "10" (to Fresh/Recirculating Air
Door Motor (V154)).

-

Operate fresh/recirculating air button (button indicator lamp lights up).

-

"Ground (GND)" is applied at terminal "9" continuously or only for a short time (depending on control module version) and " Plus" is applied at
terminal "10" continuously or only for a short time.

-

Fresh/Recirculating Air Door Motor (V154) and thus the fresh/recirculating air door moves into "recirculating air mode" position (recirculating air
intake opening - C - is opened).

-

Operate fresh/recirculating air button - F - (recirculating air, button indicator lamp goes out).

Heater Control Module, Checking|Page 7638 > < Heater Control Module|Page 7635