audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Customer Interest:|871002|Page 7888 > < All Technical Service Bulletins for High Pressure Sensor / Switch:|871002|Page 7882
Page 1
background image

Low Pressure Sensor / Switch: Customer Interest
A/C - Won't Cool

87 Air conditioning does not cool

87 10 02 

2016496/4 

June 8, 2010

Supersedes Technical Service Bulletin Group 87 number 09-06 dated November 20, 2009 for reasons listed below.

Affected Vehicles

Condition

^ Air conditioning does not cool. This symptom can be intermittent.

^ The LED in the ECON button of the AC control panel comes on intermittently.

^ The functionality of the HVAC blower is unaffected by this condition.

Technical Background

Refrigerant leak from the high pressure sensor G65. As the system leak causes the volume of available refrigerant to decrease, the correct operation of
the air conditioning system can be intermittent.

-or-

The high pressure sensor G65 malfunctions and sends implausible values to the control head J255. The air conditioning system then shuts down the
compressor.

Production Solution

Introduced a new supplier, Sensata, with an improved high pressure sensor G65.

Service

1. Recover the refrigerant from the system and measure the volume.

Make careful note of the amount of PAG oil recovered. This amount will need to be added when the system is recharged. If the recovered volume is less
than 350 g, there likely is a system leak.

2. Check for refrigerant loss at the high pressure sensor G65 with an electronic leak detector or leak detection dye. If the sensor is the source of the leak,
inspect for PAG oil residue in and around the sensor and electrical connector.