3. If only a small amount of oil is found, the refrigerant system will not have to be flushed. Clean the electrical contacts of the sensor plug.

4. If a substantial amount of refrigerant oil residue is found, the total system volume of refrigerant oil will have to be reestablished when the system is
recharged after repairs are complete. If this is not done, air conditioning compressor failure will occur.

5. If the refrigerant system has lost a substantial amount of oil and it becomes necessary to correct the system volume of PAG oil:

a. Flush the refrigerant circuit according to the repair information in ElsaWeb.

b. Drain the air conditioning compressor.

c. Replace the receiver drier.

d. Fill the system with the necessary oil quantity as specified in ElsaWeb.

6. If the high pressure sensor G65 is not the source of the leak, perform a system leak test with an electronic leak detector or leak detection dye. Repair
the leak as necessary.

Tip: If there is debris in the system, it must be flushed out and the compressor, receiver drier and expansion valve must be replaced. Make certain that a
complete system charge of refrigerant oil is included in the new compressor. Adjust volume if necessary.

7. After replacing a leaking high pressure sensor G65 and all other repairs are complete, check the cooling performance according to the repair
information in ElsaWeb.

8. If there is no system leak whatsoever and the correct volume of refrigerant is in the system, proceed with Step 9.

9. Check fault memory in address word 08 A/C / Heating Electronics. If a fault is stored in control head J255, perform the Guided Fault Finding  test
plan as specified.

10. If no fault is stored, ensure the engine is off and the key is in the on position. Then read measuring value block 1, field 4 in address word 08 A/C /
Heating Electronics.

11. Allow the refrigerant in the system to equalize for approximately 60 seconds. If the pressure value fluctuates abruptly or is implausible, replace the
high pressure sensor G65.

Tip: Remember that at 20°C ambient temperature, the pressure value should be approximately 5 bar.