audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensors after Catalytic Converter|Page 849 > < Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130|Page 846
Page 1
background image

Oxygen Sensor: Service and Repair
Oxygen Sensors after Catalytic Converter

Oxygen Sensors after Catalytic Converter

Special tools, testers and auxiliary items required

‹› ring spanner 7-piece set for oxygen sensor (3337 )

Removing

-

Remove right vehicle underbody cover - arrows -. 

-

On right side at vehicle floor, disconnect electrical harness connector -  1 - to Oxygen Sensor (O2S) Behind Three Way Catalytic Converter
(TWC) (G130) or - 2 - to Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131).

-

Remove respective connector coupling from bracket and free up electrical wire to respective oxygen sensor.

-

Remove Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) - 1 - or Oxygen Sensor (O2S) 2 Behind Three Way
Catalytic Converter (TWC) (G131) -  2 -.

Oxygen Sensors after Catalytic Converter|Page 849 > < Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) G130|Page 846