audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service and Repair|Page 5603
Page 4
background image

-

Place fluid reservoir - A - on condenser and tighten bolts.

‹› Coat O-ring seals lightly with refrigerant oil before installing. Refer to=> [ Refrigerant Circuit O-Ring Seals ] See: Description and

Operation/Refrigerant Circuit O-Ring Seals.

‹› Check O-ring seals for correct allocation and proper seating in grooves of respective mount.

‹› Hold the reservoir closed as long as possible. Remove the cap just before installing. The reservoir has a dryer cartridge, which will absorb

moisture if the reservoir is opened for a short time. This will make it then unusable.

-

Evacuate and re-charge refrigerant circuit. Refrigerant R134a - Servicing

-

Operate the A/C system after filling the refrigerant circuit. Refer to=> [ A/C System, Operating after Filling Refrigerant Circuit ] See: Service and
Repair/Procedures/A/C System, Operating after Filling Refrigerant Circuit.

‹› Note the information regarding operating the A/C system after filling => Refrigerant R134a - Servicing.

Air Door, HVAC > < Accumulator HVAC|Service and Repair|Page 5603