A3 Quattro V6-3.2L (CBRA) (2009)
-
Push spray nozzle with lines still attached back through opening and into plenum chamber.
-
Remove rubber seal - 1 - for plenum chamber cover.
-
Remove plenum chamber cover - 2 -.
CAUTION!
To avoid damage (burning) of wire connections and harness connectors, insulation and control modules, the following work steps must be
adhered to exactly! Observe operating instructions for heat gun.
-
Adjust settings on hot air gun as depicted in the illustration, this means potentiometer - 2 - for temperature setting at maximum heat output and
two-stage switch - 3 - for air quantity at position "3".