A4 V6-3.0L (AVK) (2004)
7
2 Nm
8
Heat shield
9
23 Nm
-
Serves to secure fuel filler neck and Ground (GND) connection -item 15 -.
10
Overflow hose
11
Rubber top
12
Tensioning ring
13
Seal
-
Replace if damaged
14
Cap
15
Ground (GND) connection
-
For discharging electrostatic charge
-
Installed position/check requirements Fig. 1.
-
Ensure secure seating of connector and secure wire with securing bolt for fuel filler neck -item 9 -.
-
After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter.
-
Specified value: approx. 0 Ohm
16
Vent line
17
Spring clip
18
Vent line
-
from gravity valve to EVAP canister
-
To remove, press release ring on EVAP canister
19
Vent line
-
From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-
-
To remove, press release ring on EVAP canister
-
Clipped in on fuel tank
20
Fuel tank
-
Empty if necessary, to remove components
21
Tension strap
22
Expanding clip
23
23 Nm
24
Heat shield
-
for fuel tank
25
2 Nm
26
23 Nm
Fig. 1 Installation position of Ground (GND) connection
-
Route Ground (GND) connection as shown in figure.
-
First, engage contact -1- of Ground (GND) connection into securing opening on fuel tank -4-.
-
Ensure connector -3- of Ground (GND) connection fits securely at metal ring -2- of fuel filler tube.
CAUTION: After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:
-
Specified value: approx. 0 Ohm.