A4 V6-3.0L (AVK) (2004)
Indicated on display of VAS 5051:
^
Activate basic setting by pressing button A.
^
Depress accelerator pedal and brake pedal at the same time, engine speed increases to approximately 1900 RPM.
Test requirement:
^
Accelerator pedal and brake pedal depressed at the same time, engine runs at approximately 1900 RPM.
^
Check specified values in display fields -3- and -4-.
^
Click on - button.
^
Switch over to Read measured value block.
Camshaft adjustment (exhaust), checking
Indicated on display of VAS 5051:
1. Enter display group: maximum input value = 255
^
Select function "090" in button field -2- for "display group number 090" and press Q button to confirm input.