A4 V6-3.0L (AVK) (2004)
Evaporator Drain Tube: Testing and Inspection
Evaporator Housing Drain, Checking
-
Check routing of evaporator housing drain hose, the hose should not be twisted or pinched.
-
Remove evaporator housing drain valve and evaporator housing drain hose.
-
Check distance of sound insulation mat in area of opening -E- to vehicle floor (the sound insulation mat should not touch the evaporator drain
valve).
-
Check evaporator drain valve -C-, the valve should not clotted with wax and undercoating.
NOTE: The evaporator housing drain valve -C- has no flap, the function of the flap is carried out via the spiral in the valve.
-
Check evaporator drain hose -B- for soiling (observe oval cross section of hose -D-) and clean if necessary.
-
Check evaporator housing drain of air conditioner -F- (for example using a wire) for soiling and clean if necessary.
-
If passenger compartment is moist:
-
Check air extraction outlets in passenger compartment (via luggage compartment)
-
Check recognition signal of windshield wiper operation on A/C control head -E87- Measuring Value Block, display group 014
-
Check dust and pollen filter for soiling and the cover for correct installation
-
Check various positioning motors and the pertaining levers, pay particular attention to Air Flow Flap Motor -V71- and Recirculation Flap
Motor -V113- and the pertaining levers
-
Check measured value of Evaporator Vent Temperature Sensor -G263- "Read measuring value block" display group "010". If measured value
of the sensor is too low under operating conditions specified by Service (at an ambient temperature above 0 degrees C, colder than 0 degrees
C for a long period of time), observe notes for testing cooling performance.