Evaporator Drain Tube: Testing and Inspection

Evaporator Housing Drain, Checking

-

Check routing of evaporator housing drain hose, the hose should not be twisted or pinched.

-

Remove evaporator housing drain valve and evaporator housing drain hose.

-

Check distance of sound insulation mat in area of opening -E- to vehicle floor (the sound insulation mat should not touch the evaporator drain
valve).

-

Check evaporator drain valve -C-, the valve should not clotted with wax and undercoating.

NOTE:  The evaporator housing drain valve -C- has no flap, the function of the flap is carried out via the spiral in the valve.

-

Check evaporator drain hose -B- for soiling (observe oval cross section of hose -D-) and clean if necessary.

-

Check evaporator housing drain of air conditioner -F- (for example using a wire) for soiling and clean if necessary.

-

If passenger compartment is moist:
-

Check air extraction outlets in passenger compartment (via luggage compartment)

-

Check recognition signal of windshield wiper operation on A/C control head -E87- Measuring Value Block, display group 014

-

Check dust and pollen filter for soiling and the cover for correct installation

-

Check various positioning motors and the pertaining levers, pay particular attention to Air Flow Flap Motor -V71- and Recirculation Flap
Motor -V113- and the pertaining levers

-

Check measured value of Evaporator Vent Temperature Sensor -G263-  "Read measuring value block" display group "010". If measured value
of the sensor is too low under operating conditions specified by Service (at an ambient temperature above 0 degrees C, colder than 0 degrees
C
 for a long period of time), observe notes for testing cooling performance.