A4 V6-3.0L (AVK) (2004)
-
Carefully open coolant reservoir cap (observe safety precautions when opening the cap)
-
Loosen clamp on coolant hose -B-.
-
Pull hose -B-back until the hole in the coolant hose is no longer sealed with the pipe.
-
Increase pressure in coolant circuit e.g. using V.A.G1274 hand pump.
-
Bleed heater core via coolant hose -B-until coolant exits bubble free.
-
Push coolant hose -B-on heater core pipe and tighten with clamp.
-
Add coolant if necessary.
-
Check coolant circuit for leaks, pay particular attention between coolant hoses and heater core.
-
Install driver's side storage compartment and other removed components.