audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant > < Refrigerant Lines on Compressor, Removing and Installing|Page 12365
Page 1
background image

Hose/Line HVAC: Service and Repair
Refrigerant Lines For Condenser, Removing and Installing

Refrigerant Lines For Condenser, Removing And Installing

Disconnecting

-

Remove noise insulation:

-

Remove complete front bumper:

-

Discharge A/C refrigerant system

-

Remove bolts -A- (tightening torque 20 Nm).

-

Remove refrigerant line from condenser.

NOTE:  Close all open lines and connections on condenser with suitable caps (avoid dirt and moisture from entering the system).

Connecting 

Installation is reverse of removal, noting the following:

-

Replace O-Ring-seals -B- (11.1 mm x 2.4 mm) and -C- (14.0 mm x1.8mm).

-

Check positions of refrigerant lines -A-, they must be fully engaged in bracket -B-and cannot come in contact with other components. 