A4 V6-3.0L (AVK) (2004)
Hose/Line HVAC: Service and Repair
Refrigerant Lines For Condenser, Removing and Installing
Refrigerant Lines For Condenser, Removing And Installing
Disconnecting
-
Remove noise insulation:
-
Remove complete front bumper:
-
Discharge A/C refrigerant system
-
Remove bolts -A- (tightening torque 20 Nm).
-
Remove refrigerant line from condenser.
NOTE: Close all open lines and connections on condenser with suitable caps (avoid dirt and moisture from entering the system).
Connecting
Installation is reverse of removal, noting the following:
-
Replace O-Ring-seals -B- (11.1 mm x 2.4 mm) and -C- (14.0 mm x1.8mm).
-
Check positions of refrigerant lines -A-, they must be fully engaged in bracket -B-and cannot come in contact with other components.