Note:  A few drops of ATF will escape after unscrewing flow valve connection.

-

Always replace ATF inspection plug.

-

Close inspection plug -B- before ATF temperature exceeds 45°Cl).

-

Tightening torque: 20 Nm 

Note:  At an ATF temperature above 45°C too much fluid will escape as it expands when heated. In this case the quantity of fluid in the
transmission is NOT sufficient!

50°C for tropical countries

-

Press 44 button to exit from function "08 Read data block".

-

Select diagnosis function "06 End output".

-

Switch off ignition and disconnect Data Link Connector.

ATF, changing or filling after repairs 