Disconnecting
-
Remove plenum cover.
-
Discharge A/C refrigerant system
-
Remove nuts -A- (tightening torque 25 Nm).
-
Detach refrigerant lines from evaporator and seal off all open connections.
NOTE: To seal off all open connections on evaporator -D-, sealing caps from a replacement evaporator can be used (avoid dirt and moisture from
entering the system).
Connecting
Installation is reverse of removal, noting the following:
-
Replace O-Ring-seals -B- (16.7 mm x 2.4 mm) and -C- (10.8 mm x 1.8 mm).
-
Install refrigerant lines free of stress.
-
After tightening refrigerant lines make sure that grommet -E- and line grommet -F- is properly installed.
-
Check position of refrigerant lines to evaporator, they should not come in contact with other components.