audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Lines on Compressor, Removing and Installing|Page 3057 > < Refrigerant Lines on Compressor, Removing and Installing
Page 1
background image

Hose/Line HVAC: Service and Repair
Refrigerant Lines on Evaporator Flange, Removing and Installing

Refrigerant Lines On Evaporator Flange, Removing And Installing

Disconnecting

-

Remove plenum cover.

-

Discharge A/C refrigerant system

-

Remove nuts -A- (tightening torque 25 Nm).

-

Detach refrigerant lines from evaporator and seal off all open connections.

NOTE:  To seal off all open connections on evaporator -D-, sealing caps from a replacement evaporator can be used (avoid dirt and moisture from
entering the system).

Connecting

Installation is reverse of removal, noting the following:

-

Replace O-Ring-seals -B- (16.7 mm x 2.4 mm) and -C- (10.8 mm x 1.8 mm).

-

Install refrigerant lines free of stress.

-

After tightening refrigerant lines make sure that grommet -E- and line grommet -F- is properly installed.

-

Check position of refrigerant lines to evaporator, they should not come in contact with other components. 

Refrigerant Lines on Compressor, Removing and Installing|Page 3057 > < Refrigerant Lines on Compressor, Removing and Installing