audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Before Catalytic Converter|Page 5839 > < Oxygen Sensor Before Catalytic Converter|Page 5837
Page 5
background image

-

Disconnect connector of relevant oxygen sensor

-

Undo cable ties. 

-

Remove Oxygen sensor using special tool -3337-.

Installing

NOTE:

-

The screw thread on the oxygen sensor is coated with assembly past. This past must not be allowed to penetrate the openings on the sensor. 

-

When installing, the cable ties must be re-installed at exactly the same points in order to prevent contact between the oxygen sensor wire and the
exhaust pipe. 

Tightening Torque: 55 Nm