audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Injection Control Valve|Service and Repair > < Not Available For Manufacturer's Scan Tool|Page 6448
Page 2
background image

-

Remove bolts or quick-release screws -1- and -2- and remove front noise insulation.

-

Disconnect pressure hose (arrow) at Secondary Air Injection (AIR) pump motor and blow air in with light pressure (do not use pressurized air).
-

Both combination valves must be closed, it must not be possible to blow through hose

-

Operate hand vacuum pump.
-

The relevant combination valve must open, it must be possible to blow through

If the relevant combination valve does not open:

-

Replace combination valve.

Final procedures

After repair work, the following work steps must be performed in the mentioned sequence:

1

-

Check DTC memory, "Mode 3: Check DTC memory". See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 3: Check DTC Memory

2

-

If necessary, erase DTC memory, "Mode 4: Reset/erase diagnostic data". See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 4: Check Reset/Erase Diagnostic Data

3

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness
Codes/Audi Drive Cycle/Readiness Code/With Generic Scan Tool/Readiness Code, Generating

-

End diagnosis and switch ignition off.

Air Injection Control Valve|Service and Repair > < Not Available For Manufacturer's Scan Tool|Page 6448