background image

Canister Purge Control Valve: Testing and Inspection
With Manufacturer's Scan Tool

Fuel Tank Breather, Checking

Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-, Checking

Special tools and equipment

-

VAG 1526 A

-

VAG 1527 B

-

VAG 1594 A

-

VAG 1598/31

-

VAS 5051 with VAS 5051/1

Testing for leaks

When there is no electrical supply, solenoid valve remains closed.

-

Disconnect hoses from EVAP canister purge regulator valve but leave electrical connector plugged in.

-

Connect auxiliary hose to one connection of EVAP canister purge regulator valve.

-

Connect testing and information system VAS 5051 and select vehicle system "01 - Engine electronics" in selection. Ignition must be switched on.

-

Initiate final control diagnosis and activate EVAP canister purge regulator valve -N80-. See: Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's Scan Tool/Basic Setting (Function 04)

-

The valve should click ...
... and should open and close (check by blowing into the auxiliary hose).

-

Press <- button to end function "03 - Final Control Diagnosis" [also known as Output Diagnosis Test Mode (DTM)].

If valve does not open and close properly: