Measured Values

NOTE:  Use only gold-plated terminals when servicing terminals in harness connector of throttle valve control module.

Checking function

-

Connect diagnostic tester. See: Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan
Tool Connecting/With Generic Scan Tool/Diagnostic Tester, Connecting

-

Switch ignition on.

-

In diagnostic function "33 - OBD", select "Mode 1: Checking measuring values."

-

Select the desired measuring value "PID 17: Throttle valve position (absolute)."
-

Specified value: 12 ... 16 %

-

Slowly depress accelerator pedal completely.
-

Specified value: The percentage display must increase uniformly

-

Hold accelerator pedal fully depressed; in vehicles with automatic transmission, do not depress beyond the kickdown point when doing this.
-

Specified value: 84 ... 88 %

-

Switch ignition off.

If specified values are not obtained:

-

Check voltage supply and wire connections of throttle valve control module. Pay particular attention to harness connectors that could be loose or
corroded.

-

Check Throttle Position (TP) sensor. See: Computers and Control Systems/Sensors and Switches - Computers and Control Systems/Throttle
Position Sensor/Testing and Inspection

-

Disconnect electrical harness connector at throttle valve control module.

Checking voltage supply

-

Switch ignition on.

-

Connect multimeter for voltage measurement as follows:

Harness connector

Specified value

Terminal
2 + Ground (GND)

about 5 V

2 + 6

about 5 V

-

Switch ignition off.

If specified values are not obtained:

Checking wire connections

-

Connect test box to wiring harness of Engine Control Module (ECM); ECM is not connected. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Text Box, Connecting For Wiring