Initiate final control diagnosis and actuate Evaporative Emission (EVAP) canister purge regulator valve -N80-. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's Scan Tool/Output Diagnostic Test
Mode (DTM) (Function 03)
-

Fuel pump relay (on the 9-unit-relay carrier in the driver's footwell on the left, position 1) should pull and fuel pump should run.

A -

If relay does not respond:
-

Check voltage supply of fuel pump relay.

-

Check activation of fuel pump relay.

B -

If relay is energized but fuel pump does not run:
-

Check voltage supply for fuel pump and components (via fuel pump relay).

Checking voltage supply of fuel pump relay

-

Disconnect fuel pump relay.

-

Connect multimeter as follows to measure voltage:

9-unit relay carrier in driver's footwell

Measure to

on left, position 1 terminal

1

Car body ground (GND)

-

Specified value: approx. battery voltage

-

Connect multimeter as follows to measure voltage:

9-unit relay carrier in driver's footwell

Measure to

on left, position 1 terminal

3

Car body ground (GND)

-

Switch ignition on.
-

Specified value: approx. battery voltage.

If the specified values are not obtained:

-

Check wiring connections.