If the engine shows problems in certain temperature ranges and if the temperature does not climb uniformly, the temperature signal is intermittent
and the sensor should be replaced.

If indications do not resemble description:

Checking internal resistance

-

Disconnect harness connector -2- at Engine Coolant Temperature (ECT) Sensor -G2-/-G62-.

-

Connect multimeter between terminal C and D of sensor for resistance measurement.

Range A displays resistance values for the temperature range of 0...50 degree C, range B displays resistance values for the temperature range of 50...100
degree C
.

Read-out examples:

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohm

-

80 degree C corresponds to a resistance of 275 to 375 Ohm

If specified value is not obtained:

-

Replace Engine Coolant Temperature (ECT) Sensor -G62- -item 20-.

If specified value is obtained:

Checking wire connections

-

Connect test box to wiring harness of Engine Control Module (ECM); ECM is not connected. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Text Box, Connecting For Wiring