A4 V6-3.0L (AVK) (2004)
Display Group 056
-
Exit function "04 - Basic setting" by pressing <- button.
If specified value is not obtained:
-
Check Diagnostic Trouble Code (DTC) memory again.
-
If DTC memory was erased, readiness code must be re-generated. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips,
Drive Cycles and Readiness Codes/Audi Drive Cycle/Readiness Code/With Manufacturer's Scan Tool/Readiness Code, Generating
If the idling speed is too high or too low and there are no DTCs recorded in the DTC memory, perform the following tests marked with a dot:
-
Check intake air system for unmetered air.
-
Check throttle valve control module.
-
Check whether solenoid valve for Evaporative Emission (EVAP) canister purge regulator valve is continuously open.
-
Perform adaptation of throttle valve control module.
Significance of 5-digit readout of display group 056