A4 V6-3.0L (AVK) (2004)
Climate Control Exhaust Gas Sensor: Testing and Inspection
Sensor For Air Quality -G238-, Checking
Sensor For Air Quality -G238-, Checking
Special tools and equipment
-
VAS 5051 Vehicle Diagnostic, Testing and Information System with VAS 5051/1 diagnostic cable
-
Test gas bottle D 007 855 A2
Test requirements:
-
Vehicle is in area where there is clean recirculating air (not near running engines, openings from exhaust systems, etc.)
-
Engine compartment and plenum chamber are clean (not contaminated with oil and/or fuel).
-
The engine compartment and fresh air plenum chamber were not sprayed with cleaning or preservative solutions.
Checking
-
With ignition switched off connect VAS 5051 Vehicle Diagnostic, Testing and Information System with VAS 5051/1 diagnostic cable to 16-pin
data link connector on vehicle. See: Heating and Air Conditioning/Testing and Inspection/Initial Inspection and Diagnostic Overview/Scan Tool
Connecting and Initial Checks/Connecting VAS 5051 Tester
-
Start engine.
-
Check DTC memory.
-
Select "Auto" operating mode on A/C Control Head -E87-.
-
The button for "Automatic recirculated air" -A- is activated (lamp in -A- button comes on).
-
Wait 30 seconds (warm up time of sensor for air quality -G238-).
Indicated on display of VAS 5051:
-
Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
-
Remove plenum cover.
Indicated on display of VAS 5051: