audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Sensor For Air Quality -G238-, Checking|Page 1577 > < Sensor For Air Quality -G238-, Checking
Page 2
background image

-

Display field -1- indicates request to input display group.

-

Display field -2- shows input keyboard.

-

Input via keyboard in display field 2 the desired display group umber "014" (see overview of selectable display group numbers).  See: Heating and
Air Conditioning/Testing and Inspection/Scan Tool Testing and Procedures/Measuring Value Blocks (Function 08)

-

Press -Q-button to confirm input.

-

Read indications shown in display fields -3- and -4-.

NOTE:

-

Display field -4- shows the operating conditions of fresh air/recirculated flap and display field -3- shows the condition of the air quality sensor
signal. Table of possible displays. See: Heating and Air Conditioning/Testing and Inspection/Scan Tool Testing and Procedures/Measuring Value
Blocks (Function 08)/Evaluating Measuring Value Blocks/Display Group 014

-

Specified value in display field -4-: 00 (no request for "Recirculated air mode", air conditioning in fresh air mode)

or

-

Specified value in display field -4-: 60 ("Partial recirculated air mode", fresh air and recirculated air flap open)

-

Place spray head -A- of test gas bottle over air inlet of sensor for air quality -B- (with version "1").

-

Place spray head -A- of test gas bottle over air inlet of sensor for air quality -B- (with version "2").

-

Press spray head -C- of test gas bottle for 1 second.

NOTE:

-

The content of the test bottle consists of pure oxygen with a specified amount of nitrogen oxide.

-

The sensor for air quality is in different housings, version "1" was installed at beginning of production. This sensor was replaced in a running
change to version "2", however it has the same function.

-

If the sensor comes in contact with cigarette smoke or gas from a lighter (gas is heavier than air, therefore remove and rotate sensor) it will react.

-

Read value indicated in display field -4-.
-

Specification: 10: (request for "Automatic recirculated air" mode present, request is fulfilled, A/C changes to recirculated air mode)

-

Wait a short period time (approx. 1 minute, depending on amount of test gas sprayed in sensor).

-

Read value indicated in display field -4-.
-

Specification: 00: (no request for "Recirculated air mode", air conditioning in fresh air mode)

or
-

Specification: 60 (Partial recirculated air mode)

NOTE:  In order to avoid frequent shifting of the recirculated air/fresh air flap, the request from the sensor for "Automatic recirculated air" mode
remains for at least 25 seconds (minimum duration period), even if the pollutant concentration in the air is so far reduced, that recirculated air mode
would be no longer necessary.

-

Operate switch for wiper/washer system until windshield washer pump -V5- delivered washer fluid for approx. 2 seconds.

Sensor For Air Quality -G238-, Checking|Page 1577 > < Sensor For Air Quality -G238-, Checking