Vacuum Pump: Initial Inspection and Diagnostic Overview

Vehicle diagnostic, testing and information system VAS 5051 or scan tool V.A.G1551, connecting 

Test requirements: 
-

Battery voltage at least 11 V

-

Ground (GND) connections at engine and transmission OK

-

Engine off

-

Automatic transmission in position P or N

Procedure 

-

Switch off ignition and connect VAS 5051 with accessory pack VAS 5050/1. Alternatively, connect the scan tool V.A.G 1551 with the diagnosis
lead for the vehicle diagnostic, testing and information system VAS 5051 A.

Note: 

^

The following description only covers the procedure for On Board Diagnostic (OBD when using the scan tool V.A.G 1551. When using
vehicle diagnostic, testing and information system VAS 5051, follow the procedures described in the operating instructions for the tester.

^

See note Indicated on display:

V.A.G - SELF-DIAGNOSIS HELP 1 - Rapid data transfer

V.A.G - SELF-DIAGNOSIS HELP 2 - Flash code output

and

* alternating displays

Note:  If display screen remains blank: Operating instructions for scan tool

-

Switch on ignition.

-

Switch on scan tool printer by pressing Print key. The indicator lamp in the key should light up.

-

Press key 1 for Rapid data transfer.

If the following is indicated on display:
Rapid data transfer HELP Enter address word XX 

Note:  Address word 00 starts the automatic test sequence, i.e. the fault memories of all vehicle systems with self-diagnosis capability are interrogated
by way of rapid data transfer.

-

Enter "01" for the address word Engine electronics and confirm your entry by pressing the Q key.

The scan tool V.A.G 1551 will display the control unit identification details, for example:

3B0907552A 2.7ltr. V6/5V G 0002 