Compressor Clutch Hub: Service and Repair
Run-Out Of Drive Plate With Overload Protection, Checking and Adjusting

Run-out Of Drive Plate With Overload Protection, Checking And Adjusting

-

Remove compressor.

-

Clean flange at drive plate - A -.

-

Install dial gauge - B - with dial gauge bracket - C - (e.g. special tool, bracket 387) to compressor.

-

Install measuring leads 1 2 of dial gauge - D - to flange of drive plate - A - with a pre-tension of approx. 1.0 mm.

-

Give compressor drive unit - E - several turns.

Specified value: Run-out deviation less than 0.21 mm (run-out of dial indicator, difference between lowest and highest measured value max. 0.2
mm
)

-

If run-out deviation exceeds 0.2 mm, loosen bolts at drive plate and readjust drive plate.