14. Ground (GND) connection

-

For discharging electrostatic charge

-

Installed position / check requirements, see Fig. 1

-

Ensure secure seating of connector and secure wire with securing bolt for fuel filler tube (item 8)

-

After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter.

Specified value: approx. 0 Ohm

15. Vent line
16. Vent line

-

From gravity valve to EVAP canister

-

To remove, press release ring on EVAP canister

17. Vent line

-

From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-

-

To remove, press release ring on EVAP canister

-

Clipped in on fuel tank

18. Fuel tank
19. Expanding clip
20. 23 Nm
21. Tension strap
22. Heat shield

-

For fuel tank

23. 2 Nm
24. 23 Nm

Fig. 1 Installation position of Ground (GND) connection

-

Route Ground (GND) connection as shown in figure.

-

First, engage contact -1- of Ground (GND) connection into securing opening on fuel tank -5- and then press in spacer bushing -2-.

-

Ensure connector -4- of Ground (GND) connection fits securely at metal ring -3- of fuel filler tube.

CAUTION:  After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:

Specified value: approx. 0 Ohm.