A4 Cabriolet L4-1.8L Turbo (AMB) (2005)
-
Installed position / check requirements
-
After installing, check electrical connection of metal ring at fuel filler tube to a bare area of chassis using Ohm meter
Specified value: approx. 0 Ohm
13. Ventilation line
14. Ventilation line
-
From gravity valve to EVAP canister
-
To remove, press release ring on EVAP canister
15. Ventilation line
-
From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve N80
-
To remove, press release ring on EVAP canister
-
Clipped in on fuel tank
16. Fuel tank
17. Heat shield
-
For fuel tank
18. 2 Nm
19. Heat shield
-
For fuel tank
20. 2 Nm
21. Spreader clip
22. Securing strap
-
Observe varying lengths
23. 23 Nm
Installation position of Ground (GND) connection
-
Route Ground (GND) connection as shown in figure.
-
First, hook Ground (GND) contact -1- connection into securing hole on fuel tank -5- and then press in spacer bushing -2-
-
Make sure connector of Ground (GND) connection -4- fits securely at metal ring -3- of fuel filler tube.
CAUTION: After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:
Specification: approx. 0 Ohm.