A4 Cabriolet L4-1.8L Turbo (AMB) (2005)
Specified value: approx. 0 Ohm
12. Ventilation line
13. Ventilation line
-
From gravity valve to EVAP canister
-
To remove, press release ring on EVAP canister
14. Ventilation line
-
From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve N80
-
To remove, press release ring on EVAP canister
-
Clipped in on fuel tank
15. Fuel tank
16. Heat shield
-
For fuel tank
17. 2 Nm
18. Heat shield
-
For fuel tank
19. 2 Nm
20. Spreader clip
21. Securing strap
-
Observe varying lengths
22. 23 Nm
Installation position of Ground (GND) connection
-
Route Ground (GND) connection as shown in figure.
-
First hook Ground (GND) connection contact -1- into securing hole on fuel tank -5- and then press in spacer bushing -2-.
-
Make sure Ground (GND) connector connection -4- fits securely at metal ring -3- of fuel filler tube.
CAUTION: After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:
Specification: approx. 0 Ohm.