Percentage displayed in field 1 should rise evenly. Tolerance range from 3..0.93% is not fully utilized.

Percentage displayed in field 2 should fall evenly. Tolerance range from 97..0.3% is not fully utilized.

NOTE:

-

The reason why the value indicated in display field 1 climbs, while the value indicated in display field 2 decreases, has to do with the fact that the
potentiometers (angle sensors) in the Throttle Valve Control Module -J338- run in opposite directions.

-

This means that the voltage of angle sensor 1 runs from 0 to 5 volts. (The more the throttle valve is opened, the larger the voltage; percent
indication climbs).

-

The voltage of angle sensor 2 runs from 5 to 0 volts. (The more the throttle valve is opened, the lower the voltage; the percentage decreases).

-

Exit function "08 - Read measured value block" by pressing button.

If the displays are not as described:

-

Check Throttle Valve Control Module -J338- voltage supply and wiring. Pay particular attention to connectors, which may be disconnected or
corroded.  See: Testing and Inspection/Component Tests and General Diagnostics/Throttle Valve Control Module -J338-, Checking

-

Check Sender -2- for accelerator pedal position -G185-.

Checking voltage supply to Throttle Valve Control Module -J338-.

-

Disconnect connector from Throttle Valve Control Module -J338-.

-

Switch ignition on.

-

Connect multimeter as follows to measure voltage:

Connector terminal

Specified value

2 + ground (GND)

approx. 5 V

2 + 6

approx. 5 V

If specified values are not obtained:

Checking wiring connections

-

Disconnect connector from Throttle Valve Control Module -J338-.

-

Connect test box V.A.G 1598/31 to wiring harness for Engine Control Module (ECM); do not connect Engine Control Module (ECM).  See:
Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Scan Tool Connecting/Test Box,
Connecting For Wiring and Component Test

-

Check for open circuit, short to ground (GND), or short to positive (B+) in following wiring connections: