A4 Cabriolet L4-1.8L Turbo (AMB) (2005)
-
Disconnect electrical harness connector -1- at locking flange.
NOTE: Ignore - Pos. 2 -.
-
Connect hand multimeter V.A.G 1526 B between terminal -2- and -3- for resistance measurement.
NOTE:
-
If measured value is 0 Ohm there is a short circuit. If measured value is infinite Ohms there is and open circuit in the wiring.
-
To check resistance values "tank full" or "tank empty", the fuel delivery unit must be removed and the floater of the sensor must be placed in
upper or lower end position.
-
With fuel level sensor G removed, the following values are obtained because of the greater deflection of the floater arm: