Operate starter briefly.

Specified value: approx. battery voltage

-

Switch ignition off.

If specified value is not obtained:

-

Check wire connection from Secondary Air Injection (AIR) pump relay -J299- (in 3-socket relay carrier in E-box, plenum chamber) via fuse S234
(in fuse holder, position 34) to Fuel Pump (FP) relay for open circuit according to wiring diagram.

Specified value: Wire resistance max 1.5 Ohms

Check activation of the Secondary Air Injection (AIR) pump relay

-

Remove Secondary Air Injection (AIR) pump relay -2-.

-

Connect test box to wiring harness of Engine Control Module (ECM). ECM is not connected.  See: Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Scan Tool Connecting/Test Box, Connecting For
Wiring and Component Test

-

Check the following wire connection for open circuit according to wiring diagram:

Relay carrier in E-box,

Test box

plenum chamber,
position 2
Terminal

Socket

6

46

Specified value: Wire resistance max 1.5 Ohms

-

Check the wire for short circuit to B+ and Ground (GND).

Specified value: Infinite Ohms (no continuity)

If no malfunctions are detected:

-

Replace Secondary Air Injection (AIR) pump relay -J299-.

Check voltage supply of the Secondary Air Injection (AIR) pump motor

With Generic Scan Tool|Page 3579 > < With Generic Scan Tool|Page 3577