audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 3598 > < With Generic Scan Tool|Page 3596
Page 2
background image

-

Disconnect wiring connectors from:
1. EVAP valve
2. Mass Air Flow sensor
3. Wastegate bypass regulator valve -N75-

-

Disconnect hoses -4 to 7-.

-

Disconnect hose to secondary air injection pump motor -8-.

-

Move wiring clear.

-

Unbolt air cleaner housing -9-.

-

Remove air cleaner.

NOTE:  Vacuum line to secondary air combination valve is clipped to underside of air intake hose.

-

Remove bolts (arrows) securing turbocharger to catalytic converter.

-

Lift out catalytic converter.

Installing

Install in reverse order, paying attention to the following:

-

Grease threads of oxygen sensor only with hot bolt paste G 052 112 A3; paste must not be allowed to come into contact with slits in sensor body.

-

Align exhaust system free of stress.

Tightening torques

Components

Nm

With Generic Scan Tool|Page 3598 > < With Generic Scan Tool|Page 3596