audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Not Available For Generic Scan Tool|Page 3605 > < Not Available For Generic Scan Tool
Page 1
background image

Canister Purge Control Valve: Testing and Inspection
With Manufacturer's Scan Tool

Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-, Checking

Special tools and workshop equipment required

-

V.A.G 1526 A Multimeter

-

V.A.G 1527 B LED voltage tester

-

V.A.G 1594 A Connector test kit

-

V.A.G 1598/31 Text box

-

VAS 5051 Vehicle diagnostic, testing and information system

-

VAS 5051/1 Adapter

Checking for leaks

Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- remains closed when de-energized.

-

Disconnect hoses from EVAP Canister Purge Regulator Valve -N80- but leave electrical connector connected.

-

Connect auxiliary hose to one connection of EVAP Canister Purge Regulator Valve -N80-.

-

Connect vehicle diagnostic, testing and information system VAS 5051 or V.A.G 1551 Scan Tool and select engine electronics control module with
"Address word" 01. Ignition must be switched on.

-

Initiate output Diagnostic Test Mode (DTM) and activate EVAP Canister Purge Regulator Valve -N80-.

-

The valve should click...

-

...and should open and close (check by blowing into the auxiliary hose).

-

End function "03 - Output Diagnostic Test Mode (DTM)" by pressing square button

If valve does not open or close properly:

-

Replace EVAP Canister Purge Regulator Valve -N80-.

If the fuel injector does not click:

Not Available For Generic Scan Tool|Page 3605 > < Not Available For Generic Scan Tool