audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 3622 > < With Generic Scan Tool|Page 3620
Page 3
background image

-

Remove cover for E-box, plenum chamber (arrows).

-

Pry off Engine Control Module (ECM) retaining bracket (arrows) using a screwdriver and set control module aside.

-

If installed, unclip Transmission Control Module (TCM) retaining bracket and set control module aside.

-

Connect test box to wiring harness of Engine Control Module (ECM). ECM is not connected.  See: Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Scan Tool Connecting/Test Box, Connecting For
Wiring and Component Test

-

Using wires e.g. from connector test kit V.A.G 1594 A, bridge terminals 1 and 66 on test box.

-

Switch ignition on.

-

Secondary Air Injection (AIR) Pump Relay -2- (in E-box, plenum chamber) must engage and Secondary Air Injection (AIR) Pump Motor
-V101- must run

A. Secondary Air Injection (AIR) Pump Motor runs:
-

Check voltage supply of the Secondary Air Injection (AIR) pump relay.

-

Check activation of the Secondary Air Injection (AIR) pump relay.

B. Secondary Air Injection (AIR) Pump Motor does not run:
-

Check voltage supply of the Secondary Air Injection (AIR) pump motor.

Checking voltage supply of Secondary Air Injection (AIR) pump relay

With Generic Scan Tool|Page 3622 > < With Generic Scan Tool|Page 3620