audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Tank With Attachments - Component Overview|Page 3828 > < Fuel Tank With Attachments - Component Overview|Page 3826
Page 2
background image

Specified value: approx. 0 Ohm

12. Ventilation line
13. Ventilation line

-

From gravity valve to EVAP canister

-

To remove, press release ring on EVAP canister

14. Ventilation line

-

From EVAP canister to Evaporative Emission (EVAP) Canister Purge Regulator Valve N80

-

To remove, press release ring on EVAP canister

-

Clipped in on fuel tank

15. Fuel tank
16. Heat shield

-

For fuel tank

17. 2 Nm
18. Heat shield

-

For fuel tank

19. 2 Nm
20. Spreader clip
21. Securing strap

-

Observe varying lengths

22. 23 Nm

Installation position of Ground (GND) connection

-

Route Ground (GND) connection as shown in figure.

-

First hook Ground (GND) connection contact -1- into securing hole on fuel tank -5- and then press in spacer bushing -2-.

-

Make sure Ground (GND) connector connection -4- fits securely at metal ring -3- of fuel filler tube.

CAUTION:  After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:

Specification: approx. 0 Ohm.

Fuel Tank With Attachments - Component Overview|Page 3828 > < Fuel Tank With Attachments - Component Overview|Page 3826