Disconnect hoses from Recirculating valve for turbocharger -N249- -1-; leave electrical connector connected.

-

Location: under intake manifold

NOTE:  The illustration shows a removed intake manifold viewed from below.

-

Connect test hose to valve connection marked with arrow.

-

Start Output Diagnostic Test Mode and actuate Recirculating valve for turbocharger -N249-.

Output Diagnostic Test Mode ->
Recirculating valve for turbocharger -N249

Indicated on display

-

Valve must click...

-

...and must open and close (can be checked by blowing into test hose).

If valve does not click:

-

Check internal resistance of valve.

If valve does not open or close properly:

-

Replace Recirculating valve for turbocharger -N249-.

Checking internal resistance

-

Disconnect connector from Recirculating valve for turbocharger -N249- -1-.

With Manufacturer's Scan Tool|Page 3967 > < With Manufacturer's Scan Tool