Check wiring of relay carrier, electronics box, plenum chamber, position 2, terminal 8, to connector of ignition coil terminal 1.

-

Check Motronic ECM power supply relay -J271-.

Checking activation of power output stages

-

Disconnect all injector connectors.

NOTE:  It is important to ensure that no fuel is injected during the test, as this would damage the catalytic converter. Therefore, the connectors on
the injectors must be disconnected.

-

Disconnect 4-pin connector -1- from ignition coil -2-.

-

Connect LED voltage tester V.A.G 1527 B to terminals -2- and -3- of 4-pin ignition coil connector.

-

Operate starter briefly.
-

LED voltage tester must flash (flashes briefly).

If LED does not flash:

-

Connect test box V.A.G 1598/31 to wiring harness for ECM; do not connect ECM.  See: Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Scan Tool Connecting/Test Box, Connecting For
Wiring and Component Test