audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

A/T Controls - Shudder On Acceleration|Page 4396 > < A/T Controls - Shudder On Acceleration|Page 4394
Page 2
background image

c. Obtain the owner's written consent (see attached Control Module Tuning form) for any requested repair - under warranty or outside warranty -

that requires flashing that will automatically overwrite the tuned program.

2. Ensure the TSB stating the condition in the vehicle applies to the customer complaint and the operator has a valid GeKo user ID and password.

Only perform operations explicitly stated in the TSB or RVU.

3. Check to see that the following tester requirements are met:

-

VAS 5051B Minimum Base CD Version 12.00.

-

VAS 5051B/5052 Minimum Base CD Version 12 with Brand CD 12.61 installed.

-

VAS Base Software Patch CD (Audi Technical Literature item number 42BaseSoftwarePatch) is installed in the VAS 5051 / 5052. This patch
is already in Base 12.0.

-

VAS 5051X is plugged into a 110 V AC power supply at all times.

-

Connect 5051B and 5052 to the local network.

-

For A4s after VIN 8E_5A400000 (B7 Platform), always use the 6017B K Line Adapter to ensure communication to all modules.

-

If the wireless VAS 5054A transmitter head is used in conjunction with a VAS 5052A or VAS 5051B tester, the transmitter head and the tester
must be connected with a USB cable.

-

Ensure the Windows power savings are set correctly (disabled) for VAS testers operating with an open Windows interface where users have
access to all regular PC operating system functions (implemented by running the Base V14.00.00 Recovery DVD).

NOTE:  If the Windows screensaver activates during a control module software update and the hard drive shuts down as a result of the power
settings, a control module failure may result. Refer to Service Circular ATE- 08-23 for more information.

NOTE:  Do not use a 6017 or 6017 A while flashing. Doing so may result in complete control module failure.

4. Check to see that the following vehicle requirements are met:

-

Battery must have a minimum no-load charge of 12.5 V.

-

Connect vehicle to a powered Audi-approved battery charger. Do not use a trickle charger or battery maintainer.

-

Turn off the radio and all other accessories, and when necessary, switch running lights off by applying the emergency brake or through the
MMI option menu.

-

Turn off any appliances with high electromagnetic radiation (such as mobile phones).

-

If communication with a module cannot be properly established, appropriate repairs must be made before attempting SVM. If the tester cannot
communicate with a module, the tester cannot flash software onto the module.

5. In the VAS Tester, enter into GFF program. Address or record all DTCs related to a customer concern before continuing. Sporadic communication

DTCs will be created during the flash procedure and must be erased with all other sporadic DTCs by GFF after exiting the flash test plan.

6. Enter the SVM update into the User Test Plan by selecting the following inside GFF:

Go to >> Function/Component Selection >> Problem Related Hardware and Software Update >> Direct Input: SVM code for problem related
update.

7. Follow the SVM update procedure and enter the SVM Action Code found in the Conditional TSB when prompted.

8. Enter your GeKo ID when requested and data will be transmitted to the SVM server, which will respond with instructions to continue. The

procedure may include one, or any combination of the following, for one or multiple control modules as specified in the TSB/RVU:

-

Check a control module.

This will occur when SVM does not recognize the control module as valid for the vehicle. If there is no customer concern and no DTC
regarding this control module, report the issue to the Technical Assistance Center (TAC) with the required information specified in the
Additional Information section below. Always report MMI issues to the TAC before attempting a repair.

A/T Controls - Shudder On Acceleration|Page 4396 > < A/T Controls - Shudder On Acceleration|Page 4394