audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 2682 > < With Generic Scan Tool|Page 2680
Page 4
background image

-

Connect voltage tester VAG 1527 B as follows:

3-way relay carrier in electronics

Measure to

box in plenum chamber, position
2, contact
6

Engine Ground

-

Start output Diagnostic Test Mode and actuate Secondary AIR pump relay -J299-.
-

LED must flash

If LED does not flash:

-

Switch off ignition.

-

Connect test box VAG 1598/31 to engine control module wiring harness. Engine control module must not be connected:

-

Check for open circuit and short to Ground/positive in following wiring connection:

3-way relay carrier in electronics

Test box VAG 1598/31

box in plenum chamber, position

socket

2,contact
6

66

-

If necessary, eliminate open circuit/short circuit.

If no fault is found:

-

Replace Secondary AIR pump relay -J299-.

Checking power supply for secondary AIR pump motor

With Generic Scan Tool|Page 2682 > < With Generic Scan Tool|Page 2680