audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 353 > < With Generic Scan Tool|Page 351
Page 3
background image

-

Perform following checks marked with a dot:

-

Check fuse -S130- (40 A) in 3-way relay carrier of electronics box in plenum chamber, position 7.

-

Check for open circuit in wiring from battery+ (terminal 30) to fuse -S130- to Secondary AIR pump relay -J299- (in 3-way relay carrier of
electronics box in plenum chamber, position 2).

-

Connect multimeter and measure voltage as follows.

3-way relay carrier in electronics

Measure to

box in plenum chamber, position
2, contact
4

Engine Ground

-

Briefly operate starter.
Specification: approx. battery voltage

If reading does not match specification:

-

Perform following checks marked with a dot:

-

Check fuse -S234- (in fuse box, position 34).

-

Check for open circuit in wiring from Secondary AIR pump relay -J299- (in 3-way relay carrier of electronics box in plenum chamber) to fuel
pump relay via fuse -S234- (in fuse box, position 34):

Checking actuation of secondary AIR pump relay

-

Switch off ignition.

-

Disconnect secondary AIR pump relay.

With Generic Scan Tool|Page 353 > < With Generic Scan Tool|Page 351