Remove sound insulation (arrows).

-

Disconnect connector from Secondary AIR pump motor -V101- (arrow).

-

Location: right front in engine compartment below air cleaner housing

-

Connect voltage tester VAG 1527 B between contacts 1 and 2.

-

Start output Diagnostic Test Mode and actuate Secondary AIR pump relay -J299-.
-

LED must flash

If LED does not flash:

-

Perform following checks marked with a dot:

-

Check for open circuit in wiring from contact 1 of connector to secondary AIR pump relay -J299- (in 3-way relay carrier in electronics box of
plenum chamber, position 2).

-

Check for open circuit in wiring from contact 2 of connector to Ground:

If no fault is found:

-

Replace Secondary Air Injection (AIR) pump motor -V101-.