Disconnect electrical harness connector -2-.
Checking voltage supply
-
Switch ignition on.
-
Connect multimeter for voltage measurement as follows.
Harness connector
Specified value
Terminal
1 + Ground (GND)
about 5 V
1 + 5
about 5 V
2 + Ground (GND)
about 5 V
2 + 3
about 5 V
-
Switch ignition off.
If specified values are not obtained:
Checking wire connections
-
Connect test box to wiring harness of Engine Control Module (ECM). ECM is not connected. See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Scan Tool
Connecting/Test Box, Connecting For Wiring and Component Test