audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fault table > < Performing final control diagnosis
Reading measured value block
Reading measured value block
–  Connect fault reader and select function "engine electronics" → Chapter.
–  Press key.
   
Indicated on display (function selection):
–  Press keys 0 and 8 for the function “Read measured value block”.
–  Confirm entry with Q key.
 
Vehicle system - test               HELP
Select function XX                    
Indicated on display:
–  Press keys 0, 0 and 8.
–  Confirm entry with Q key.
Display group 008
 
Read measured value block         HELP
Enter display group number           XXX
Read measured value block8 →Indicated on display:
operated/not operatedPump off Pump onXXX mbarTest off Test on 
   Test
t  Test (short test) off
t  Test (short test) on
  Vacuum
t  Vacuum measured at brake servo unit
t  Display for vented brake servo unit approx. 960, for evacuated brake servo unit approx. 450, depending on ambient pressure.
 Vacuum pump
t  Pump off
t  Pump on
–  If pump does not run although display shows “Pump on” conduct fault finding according to current flow diagram.
Brake pedal:
t  Brake pedal not depressed
t  Brake pedal depressed
–  In the event of any deviations check brake light switch.

   

Fault table > < Performing final control diagnosis