Exploded view of components
Exploded view of components
HD = High-pressure end
ND = Low-pressure end
   
1 - Air conditioning system compressor regulating valve -N280-
q   Checking actuation and operation → Chapter → Anchor1)
2 - Compressor
q   Detaching compressor from holder/re-attaching → Chapter and → Anchor1)
q   When installing refrigerant pipes and corresponding holder, make sure there is sufficient distance between belt, holder and pulley.
q   Type of compressor differs depending on engine (attached to right or left of engine, 6-cyl. diesel or petrol engine) → Parts List
q   Different types of compressor are fitted depending on country version (e.g. “Denso” type designation “6 SEU” for Europe and “7 SEU” for hot countries) → Parts List
3 - Pulley/compressor drive unit to engine
q   Replacing pulley → Chapter
q   Removing and installing poly V-belt → Anchor1) and → Engine, mechanics; Rep. Gr.13
q   Poly V-belt assignment → Parts List
q   Checking/replacing compressor drive unit → Chapter
  Note
t  A rubber element is fitted between pulley/drive unit and drive shaft of compressor to protect belt/drive gear unit in the event of compressor blockage or stiffness.
t  If the compressor is not operating smoothly, the rubber element interrupts power transmission to the compressor.
t  A rubber element is fitted between the engine and compressor to protect the drive gear unit in the event of compressor blockage or stiffness.
t  The rubber element absorbs any vibration occurring during compressor operation (damper function in the case of torque fluctuations).
4 - Oil drain plug
5 - Pressure relief valve
6 - Connection with valve
7 - High-pressure sender -G65- → Anchor1)
q   Removing and installing → Chapter
q   Checking signal → Chapter
8 - Condenser
9 - Cap
q   With seal
q   Always to be screwed on
10 - Service connection
q   High-pressure end
q   For specialist air conditioner workshops for measuring, draining and filling
11 - Screw connection in refrigerant pipe
12 - Restrictor
q   Fitted in screw connection -item → Item-
13 - Evaporator
14 - Service connection
q   Low-pressure end
q   For specialist air conditioner workshops for measurement and drainage
15 - Cap
q   With seal
q   Always to be screwed on
16 - Reservoir

   

Removing and installing high-pressure sender G65 > < Servicing work on refrigerant circuit