audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Test steps "1” to "4” > < Checking
List of electrical checks at the operating and display unit, Climatronic control unitJ255
List of electrical checks at the operating and display unit, Climatronic control unit -J255-
  Note
Various items of information are transmitted via the convenience data bus system (reading measured value block → Chapter). There are no electrical checks provided for this information.
   
Test stepComponent checkedPage
1
t  Power supply and earth connection of operating and display unit, Climatronic control unit -J255-
→ Chapter
2
t  Fresh-air intake duct temperature sensor -G89-
t  Right vent temperature sender -G151-, front vent temperature sender -G152-, left footwell vent temperature sender -G261-, right footwell vent temperature sender -G262-, evaporator outflow temperature sender -G263-
→ Chapter
3
t  Wiring to fresh air blower control unit -J126- and fresh air blower -V2-
→ Chapter
4
t  Control motors of air conditioner and corresponding potentiometers -central flap control motor -V70- / central flap control motor potentiometer -G112-, air flow flap control motor -V71- / air flow flap control motor potentiometer -G113-, defroster flap control motor -V107- / defroster flap control motor potentiometer -G135-, air recirculation flap control motor -V113- / air recirculation flap control motor potentiometer -G143-, left temperature flap control motor -V158- / left temperature flap control motor potentiometer -G220-, right temperature flap control motor -V159- / right temperature flap control motor potentiometer -G221-
→ Chapter
5
t  Pressure signal from high-pressure sender -G65-
→ Chapter
6
t  Actuation of air conditioning system compressor regulating valve -N280-
→ Chapter
7
t  Signal from sunlight penetration photosensor -G107-
→ Chapter
8
t  Input for activation signal for actuation of operating and display unit, Climatronic control unit -J255- (e.g. from service installed auxiliary heater)
→ Chapter

   

Test steps "1” to "4” > < Checking