Note t
| The auxiliary heater operating time is calculated on the basis of the setting in the driver information system (DIS) by the control unit in dash panel insert -J285-. The adjustable ON time (currently 15....60 min (900....3600 sec.)) is transmitted by way of the convenience data bus system to the auxiliary heater control unit -J364- together with the activation signal. |
t
| The auxiliary heater is switched on and off by the control unit in dash panel insert -J285-. If the control unit in dash panel insert -J285- transmits an activation signal for more than 3600 sec., the auxiliary heater control unit -J364- switches off the auxiliary heater on completion of the safety margin (160 to 400 sec. depending on version of auxiliary heater control unit -J364-). |
t
| The maximum operating time entered in the auxiliary heater control unit -J364- and thus permissible of 3870 sec. at present may, depending on version of auxiliary heater control unit -J364-, also be slightly longer or shorter. |
|
|
|