A4 Mk1
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||
The engine must switch off. Central locking must switch to "open". The hazard warning lights and interior lights come on.
Notes: After this step has been performed, fault code 01366 will be stored in the CL control unit. After completing the final control diagnosis the fault memory of the CL control unit must be read and this fault must be erased => Page01-72. After this step has been performed, several faults will be stored in the fault memory of the engine control unit. After completing the final control diagnosis the fault memory of the engine control unit must be read and this fault must be erased. Refer to ignition and injection in the Workshop Manual in Repair Group: 01 Self-diagnosis; erasing and interrogating fault memory. According to engine type, the fuel supply shuts off as of week 18.99 onwards. If the engine does not start, check whether the fuel supply shut off in the engine has been activated. => Current flow diagrams binder If the engine does not start and the fuel supply shut off in the engine has been activated, check wiring to the engine. => Current flow diagrams binder |
→ Indicated on display: |
|
||
|
→ Indicated on display: |
|
||